150kw Marine generator
Payment Terms: |
T/T,L/C |
Place of Origin: |
Chongqing, China (Mainland) |
Product Detail
Model No.:
BMMPPMGY150
Production Capacity:
500 Set/Sets / Month
Delivery Date:
about 30 days
Brand Name:
Bochi
Frequency:
50HZ
Rated Voltage:
400
Intake way:
Turbo-cooled&inter-cooled
Starting type:
Electric start
Min.fuel consumption g/(KW.h):
≤195
Lw Noise limit:
≤98
Net Weight(kg):
2600
Means of Transport:
Ocean,Land,Air
Packing:
Wooden case
Output Type:
AC Three Phase
Speed:
1500r/min
Rated Power:
80kw
Rated Current:
271
No. of Cylinder - bore*stroke:
6 - 120*145
Total displacement(L):
9.839
Oil capacity(L):
34
Regulator approach:
AVR
Packing size L*W*H(mm):
2500*960*1500
1.Yuchai engine with Sanbo,Lan electric,Stanford,Marathon generator
3.over 10000 hours gurantee
4.Much lower fuel consumption
Gensets Model | BMMPPMGY150 | BMMPPMGY160 | BMMPPMGY200 | BMMPPMGY250 | BMMPPMGY300 |
Rated Capacity(KVA) | 150/188 | 160/200 | 200/250 | 313 | 300/375 |
Engine | Diesel Model | YC6M240C | YC6M260C | YC6MK300C | YC6T400C | YC6T450C |
Rated power/Speed(KW/r/min) | 176/1500 | 192/1500 | 219/1500 | 294/1500 | 330/1500 |
Type | Vertical,inline,water-cooled,4 stroke |
Intake way | Turbo-cooled&inter-cooled |
No. of Cylinder - bore*stroke | 6 - 120*145 | 6 - 145*165 |
Starting type | Electric start |
Total displacement(L) | 9.839 | 16.35 |
Min.fuel consumption g/(KW.h) | ≤195 | ≤192 |
Oil capacity(L) | 34 | 52 |
Lw Noise limit | ≤98 |
Generator | Lan Generator Model | TZHW-150 | TZHW-160 | TZHW-200 | TZHW-250 | TZHW-300 |
Rated voltage | 400 | 400 | 400 | 400 | 400 |
Current(A) | 271 | 289 | 361 | 451 | 541 |
Regulator approach | AVR |
Freq.(Hz) | 50 |
Power factor(CosΦ) | 0.8 lagging |
Phase | 3-phase |
Package | Net Weight(kg) | 2600 | 2600 | 2800 | 2500 | 3130 |
Packing size L*W*H(mm) | 2500*960*1500 | 2800*1020*1700 |
The main technical indexes
1.characteristic of voltage regulation
ratio of steady state voltage regulation ≤±2.5% ratio of transient state voltage regulation ≤±20-15%
steady time ≤1.5 ratio of voltage fluctuation ≤±1% voltage setting range of non-load 95-105%rated current
2.performance of governoring
ratio of steady governoring ≤5% ratio of transient governoring ≤±10%
steady time ≤5S ratio of rotating speed fluctuation ≤±0.5%
3.The generator set can overload 10% of the rated power for an hour after 12hours of rated power continuously .
4.Generator set can keep parallel running for a long time. The generator set can run steadily when the load changes at 20%-100% of rated power factor and can transform the load's active power and reactive power steadily. The active power's distribution degree can’t exceed 15% of the generator’s rated power, and the reactive power’s distribution degree can’t exceed 10% of the generator’s rated power.